ADAM-4015

ADAM-4015 – 6-ch RTD Module with Modbus by Advantech

The ADAM-4015 is a 6-channel RTD input module from Advantech designed for precise temperature measurement in industrial automation applications. This RS-485 I/O module supports Pt, Balco, and Ni RTD types with 2 and 3-wire connections, offering accuracy of ±0.1% typical. It features both ASCII command and Modbus/RTU protocols, burnout detection for sensor fault monitoring, and operates within -10 to 70°C environments. With CE, FCC, and UL Class I Division 2 certifications, the ADAM-4015 is suitable for hazardous location deployments. Available from Recab, your Nordic partner for Advantech remote I/O solutions.
Description
The ADAM-4015 from Advantech is a robust 6-channel RTD input module engineered for accurate temperature sensing in demanding industrial environments. This RS-485 based I/O module provides six differential input channels supporting 2 and 3-wire RTD connections, accommodating multiple RTD types including Pt 100, Pt 1000, Balco 500, Ni 50, and Ni 508 sensors across various temperature ranges from -200°C to 600°C. The module delivers exceptional measurement accuracy of ±0.1% typical with a common mode rejection ratio of 120 dB at 50/60 Hz, ensuring reliable readings even in electrically noisy environments. Communication flexibility is provided through support for both ASCII command and Modbus/RTU protocols over the RS-485 interface, enabling seamless integration with diverse automation systems and SCADA platforms. The integrated burnout detection feature alerts operators to sensor failures, enhancing system reliability and reducing downtime. A system watchdog timer with 1.6-second timeout and communication watchdog ensure continuous operation. The ADAM-4015 operates on an unregulated 10 to 30 VDC power supply with low power consumption of just 1.2 W, making it energy efficient for distributed installations. Certified to CE, FCC, and UL Class I Division 2 standards, this module is approved for deployment in hazardous locations where flammable gases or vapors may be present. The compact design with plug-in terminal blocks accepting 14 to 28 AWG wire simplifies installation and maintenance. Ideal for process control, building automation, HVAC monitoring, and industrial machinery temperature sensing applications across manufacturing, energy, and critical infrastructure sectors. Available from Recab, your Nordic partner for Advantech remote I/O solutions.
Features
  • Six differential RTD input channels supporting Pt, Balco, and Ni sensor types
  • High measurement accuracy of ±0.1% typical with 120 dB common mode rejection
  • Dual protocol support with ASCII command and Modbus/RTU communication options
  • Integrated burnout detection for automatic sensor fault monitoring and alerting
  • UL Class I Division 2 certification for safe deployment in hazardous locations
  • Low power consumption of 1.2 W enabling energy efficient distributed installations
Specifications
Channels 6 differential
Input Connections 2, 3-wire
Input Impedance 10 MΩ
Input Type Pt, Balco and Ni RTD
Accuracy ±0.1% (Typical)
CMR @ 50/60 Hz 120 dB
Span Drift ± 25 ppm/°C
Zero Drift ± 3 µV/°C
Supported Protocols ASCII command and Modbus/RTU
Burnout Detection Yes
Power Consumption 1.2 W @ 24 VDC
Power Input Unregulated 10 ~ 30 VDC
Operating Temperature -10 ~ 70°C (14 ~ 185°F)
Operating Humidity 5 ~ 95% RH
Certification CE, FCC, UL, UL Class I Division 2
  • Process control temperature monitoring in manufacturing facilities
  • HVAC system temperature sensing for building automation
  • Industrial machinery thermal management and protection systems
  • Hazardous location temperature measurement in petrochemical plants