Get connected

ADAM-4118-C, ADAM-4150-C, ADAM-4168-C

ADAM-4000 – RS-485 I/O Modules with Modbus by Advantech

The Advantech ADAM-4000 series comprises robust RS-485 I/O modules designed for industrial automation and remote monitoring applications. This family includes the ADAM-4118 8-channel thermocouple input module, ADAM-4150 15-channel digital I/O module, and ADAM-4168 8-channel relay output module. All modules support both ASCII Command and Modbus/RTU protocols, feature 3000 VDC isolation voltage, and operate across an extended temperature range of -40 to 85°C. With wide power input from 10 to 48 VDC and comprehensive overvoltage protection, these modules deliver reliable data acquisition in demanding environments. Available from Recab, your Nordic partner for Advantech industrial I/O solutions.
Description
The Advantech ADAM-4000 series represents a comprehensive family of RS-485 I/O modules engineered for robust industrial data acquisition and control applications. This versatile product line includes three specialized modules: the ADAM-4118 offering 8 differential thermocouple input channels supporting J, K, T, E, R, S, B, and N type thermocouples along with voltage and current measurement modes; the ADAM-4150 providing 15 channels of digital I/O with 7 digital inputs and 8 open collector outputs supporting counter, frequency, and pulse output functions; and the ADAM-4168 featuring 8 Form A relay outputs rated for both AC and DC loads. All modules in the ADAM-4000 family share common industrial-grade specifications including 3000 VDC isolation voltage, extended operating temperature from -40 to 85°C, and wide power input acceptance from 10 to 48 VDC unregulated. The modules communicate via RS-485 interface and support both ASCII Command and Modbus/RTU protocols for seamless integration into existing SCADA and automation systems. Built-in watchdog timers ensure system reliability, while plug-in terminal block connectors simplify field wiring. The ADAM-4118 thermocouple module features 16-bit resolution, burnout detection, and built-in TVS/ESD protection for signal integrity. The ADAM-4150 digital I/O module supports 3 kHz counter input and 1 kHz pulse output capabilities, while the ADAM-4168 relay module delivers 100 Hz pulse output with 10ms typical total switching time. These modules are ideal for factory automation, process control, building management, energy monitoring, and environmental monitoring applications. FCC and CE certified with RoHS compliance, the ADAM-4000 series provides reliable remote I/O connectivity for industrial networks. Available from Recab, your Nordic partner for Advantech industrial I/O solutions.
Features
  • Wide operating temperature range from minus forty to eighty five degrees Celsius
  • High isolation voltage of three thousand VDC protects against electrical interference
  • Supports both ASCII Command and Modbus RTU protocols for flexible integration
  • Wide power input acceptance from ten to forty eight VDC unregulated supply
  • Built-in system and communication watchdog timers ensure reliable operation
  • Plug-in terminal block connectors accept fourteen to twenty two AWG wire
Specifications
Power Input Unregulated 10 ~ 48 VDC
Isolation Voltage 3,000 VDC
Interface RS-485, micro USB
Supported Protocols ASCII Command and Modbus/RTU
Operating Temperature -40 ~ 85°C
Operating Humidity 5 ~ 95% RH
Watchdog Timer System (1.6 second) & Communication
Connector 2 x plug-in terminal blocks (#14 ~ 22 AWG)
ADAM-4118 Power Consumption 0.5W @ 24 VDC
ADAM-4118 Analog Input Channels 8 differential
ADAM-4118 Resolution 16-bit
ADAM-4150 Power Consumption 1.6 W @ 24 VDC
ADAM-4150 Digital I/O Channels 7 DI + 8 DO
ADAM-4168 Power Consumption 2.3 W @ 24 VDC
ADAM-4168 Relay Output Channels 8 Form A
  • Factory automation systems requiring remote thermocouple temperature monitoring
  • Process control applications with distributed digital input output requirements
  • Building management systems needing relay control and sensor integration
  • Energy monitoring installations using Modbus RTU communication protocols